Jandy R0465600 – Bulkhead Assembly with O-Ring
Product Overview
The Jandy R0465600 is a complete bulkhead assembly replacement for select Jandy CV, CL, DEV and DEL series pool filters. It includes the bulkhead fitting and a pre-installed O-ring, allowing for leak-free sealing and quick maintenance.
Key Features
- OEM bulkhead assembly with integrated O-ring to replace worn or leaking connections.
- Compatible with multiple filter families: CV340/460/580, CL340/460/580, DEV48/60, DEL48/60.
- Provides a reliable seal to maintain proper filter performance and prevent bypass or leaks.
- Durable construction designed to hold up in high-flow pool filter environments.
Technical Specifications
- Part Number: R0465600
- Includes: Bulkhead fitting + O-ring
- Compatible Filter Models: CV/CL series cartridges and DEV/DEL series D.E. filters
- Application: Replacement bulkhead assembly for Jandy filtration systems
Applications & Compatibility
This bulkhead assembly is designed for use in Jandy filtration systems where the original bulkhead or seal has become worn or leaking. Ideal for CV and CL cartridge filters (340, 460, 580 sizes) and DEV/DEL D.E. filters (48, 60 sizes). Verify your filter model number before purchasing.
Installation Instructions
- Shut off the pump and relieve pressure in the filter system before servicing.
- Remove the filter tank lid or clamp and disconnect plumbing as needed to access the bulkhead.
- Remove the old bulkhead and clean the tank face, inspect the tank wall for cracks or damage.
- Position the new R0465600 assembly, ensure the O-ring is seated properly and threads align cleanly, then tighten to factory torque specifications.
- Reinstall the tank lid/clamp, restore pump operation and check carefully for any leaks at the bulkhead connection.
Troubleshooting
-
Leak at bulkhead seam: Confirm the O-ring is properly seated, clean sealing surfaces, and ensure the bulkhead is tightened correctly.
-
Bypass or poor filtration performance: Check that the bulkhead assembly is correctly installed and that internal filter elements are properly seated.
-
Cracks or deformation around tank wall: Inspect tank wall for damage — replacing the bulkhead will not fix structural tank issues.
Maintenance Tip
Inspect the bulkhead connection annually during filter servicing. If you notice signs of leakage, corrosion, or looseness, consider replacing with the R0465600 to maintain system integrity. Keeping the seal in good condition helps avoid costly pool downtime and protects other pump and filter components.